image
image
image
image
Miniature S Beam Load Cell

Miniature S Beam Load Cell

LC2306
Miniature S Beam Load Cell Compact design, alloy steel or stainless steel construction, Small capacity, high accuracy. IP65+rated with temperature compensation. Output options: mV/V, 4-20mA, RS485. Miniature s beam load cell Ideal for micro scales, automation, medical devices, and industrial force control. Operating range: -20°C to +60°C, 150%FS overload protection.
Quantity:
Contact Now
add to cart
All Products
Miniature S Beam Load Cell Compact design, alloy steel or stainless steel construction, Small capacity, high accuracy. IP65+rated with temperature compensation. Output options: mV/V, 4-20mA, RS485. Miniature s beam load cell Ideal for micro scales, automation, medical devices, and industrial force control. Operating range: -20°C to +60°C, 150%FS overload protection. (miniature s beam load cell, Saintbond miniature s beam load cell, 10n load cell )
 
 
LC2306 Miniature S Beam Load Cell Dimension:
                                      
Cap.ABCDEM
0-5N-30N1619.156.717M3 Depth 3 mm
0-50N1619.167.517M4 Depth 3 mm
Note:
1:Screws should not be screwed too deep and shall not exceed 4 millimeters. You should not touch the middle part of the sensor so as not to affect the measurement result.
When the
2:Sensor is installed, the two sides of the cover plate can not be contacted with the middle cylinder, so as to avoid measuring the result
 
                                   
CapacityABCM
0-100N-500N1619.16M4 Depth 3 mm
0-200N-2KN264012M8 Depth 8 mm
 
Note:screws must not be screwed too deep when they are installed. You should not touch the middle part of the sensor so as not to affect the measurement result.
 
LC2306 Miniature S Beam Load Cell Description:
Ultra small installation size, width of only 5 mm, height of 19.1 mm; high speed dynamic response output, high accuracy; measuring force: internal thread tension or compression direction. Widely used in automatic force detection, typical applications: key detection.
 
LC2306 Miniature S Beam Load Cell Technical Parameter:
Capacity0-5N~2000NMaterialStainless Steel
Rated output2.0 ±10%  mV/VOutput Impedance350±3Ω
Non-linearity0.05 % F.S. Insulation>5000MΩ/10VDC
Hysteresis0.05 % F.S.Recommended Excitation2.5-5V
Repeatability0.05 % F.S.Excitation max10V
Creep(30min)0.05 % F.S.Compensated Temp Range-10~60℃
Temp Effect On Output0.1 % F.S./ 10℃Operating Temp Range-20~80℃
Temp Effect On Zero0.1 % F.S./ 10℃Safe Load1.2
Protection ClassIP 65 Ultimate Load Limit1.5
Input Impedance350±15ΩCable Length∅2-3 x 3m