image
image
image
image
tank scale load cells

Ball Type Load Cell

LC110Y
Ball type load cell also commonly known as a digital load scales, tank scale load cells, are designed for truck and rail scales. Multiple load cells are used in each installation. Our range includes alloy tool steel tank scale load cells and stainless steel tank scale load cells offered with environmental ratings up to IP68 suitable for demanding situations where water and dirt are common. Each ball type load cell for weigh bridge can be supplied individually or combined with our state of the art instrumentation for a complete weigh system.
Quantity:
Contact Now
add to cart
All Products

Ball type load cell also commonly known as a digital load scales,tank scale load cells, are designed for truck and rail scales. Multiple load cells are used in each installation. Our range includes alloy tool steel tank scale load cells and stainless steel tank scale load cells offered with environmental ratings up to IP68 suitable for demanding situations where water and dirt are common. Each ball type load cell for weigh bridge can be supplied individually or combined with our state of the art instrumentation for a complete weigh system.

Digital load scales,tank scale load cells,ball type load cell is a type of transducer that converts the force exerted by a vehicle’s weight into an electrical signal. This signal can then be processed and displayed as a weight value, allowing for the accurate determination of the vehicle’s load.

Dimention:mm

                                                   

Technical Parameter:

Rated Load:5/10/20/25/30/40/50tOperating Temp. Range:-30~+70℃
Sensitivity:(2.0±0.1%) mV/VMax. Safe Over Load:150,120 (40~50t)%F.S
Combined Error:±0.02% F.SUltimate Over Load:300,200(40~50t)%F.S
Creep Error(30min):±0.01% F.SRecommend Excitation:10~12V DC
Zero Balance:±1% F.SMaximum Excitation:15V DC
Tco:±0.02% F.S/10℃Sealing Class:IP67/IP68
Tc Span:±0.02% F.S/10℃Element Material:Alloy/Stainless Steel
Input Resistance:750±5ΩCitation:GB/T7551-2008/ OIML R60
Insulation Resistance:≥5000MΩCable:Length=13m
Output Resistance:703±2Ω,703±5 Ω(L≥15m)Mode Of Connection:Red(Input+),Black(Input-),
Green(Output+),White(Output-)