LC406
he LC406 weigh cells / canister load cell is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the LC406 canister load cell probably already complies.

Use the LC406 canister load cell in new truck, railroad track and other heavy capacity weighbridge applications or as a replacement for cells in an old weighbridge to enhance its performance,The LC406 weigh cells is ideally suited to this application in Vehicle Weighing.
Quantity:
Contact Now
add to cart
All Products
The LC406 weigh cells / canister load cell is approved for use in various applications in Europe, Asia, America and almost everywhere else in the world. If an approval is required, the LC406 canister load cell probably already complies. (weigh cells, canister load cell, 200 ton load cell )
 
Use the LC406 canister load cell in new truck, railroad track and other heavy capacity weighbridge applications or as a replacement for cells in an old weighbridge to enhance its performance,The LC406 weigh cells is ideally suited to this application in Vehicle Weighing.
 
The capacity range from 20t to 200 ton load cell 300t allows the weighing of big tanks and silos with ease. The stainless steel design (20t–300t), hermetic sealing and IP68 protection provides the best reliability in tank weighing applications.
 
LC406 Weigh Cells Column structure load cell widely used in industrial automation measurement and control system in cement, coal and other industries of electronic truck scale, railway track scale, platform scale, hopper scale and other kinds of weighing, measuring force.
 
LC406 Weigh Cells Dimension:mm
 
Cap/SizeABCDEFSR
20~40t7610237.835.515019160
50~60t7610237.835.515019305
100~120t10212253.850.615019305
200~250t1591798075.319525400
300t19221810699.225029900
 
 
LC406 Weigh Cells Technical Parameter:
Rated Load:20/30/40/50/60/100/120/200/250/300t
Sensitivity:(2.0±0.1%)m V/VOperating Temp. Range:-30~+70℃
Combined Error:±0.03% F.SMax. Safe Over Load:150%F.S
Creep Error(30min):±0.02% F.SUltimate Over Load:250%F.S
Zero Balance:±1% F.SRecommend Excitation:10~12V DC
Tco:±0.02% F.S/10℃Maximum Excitation:15V DC
Tc Span:±0.02% F.S/10℃Sealing Class:IP67/IP68
Input Resistance:1160±10ΩElement Material:-A: Alloy Steel, -SS: Stainless Steel
Output Resistance:1000±3ΩCable:Length=12m(20,30,40t), 16m(50,100t), 18(20~300t)
Insulation Resistance:≥5000MΩCitation:GB/T7551-2008/ OIML R60