image
image
image
image
Clamp On Load Cell

Clamp On Load Cell

LC104
Clamp-On Wire Rope Load Cells /Rope Clamp Tension Load Cell , This non-invasive sensor installs in minutes without cable alterations, delivering real-time, accurate tension data. Perfect for cranes, shipping, and heavy equipment. It ensures safety, prevents overloads, and works seamlessly with monitoring systems. Robust and easy to use.
Quantity:
Contact Now
add to cart
All Products
Clamp-On Wire Rope Load Cells /Rope Clamp Tension Load Cell , This non-invasive sensor installs in minutes without cable alterations, delivering real-time, accurate tension data. Perfect for cranes, shipping, and heavy equipment. It ensures safety, prevents overloads, and works seamlessly with monitoring systems. Robust and easy to use. ( Clamp On Load Cell, Rope Clamp Tension Load Cell, Clamp-On Wire Rope Load Cells )
 
LC104 Clamp On Load Cell Specification:
This Clamp-On Wire Rope Load Cells /Rope Clamp Tension Load Cell  has been designed to provide a trip point for lifting systems which have a dead end wire rope. The trip point provides a signal that the user may employ depending on his requirements, e.g.
✅ For load limiting in lifting systems
✅ To limit the speed as a function of the load on traversing
✅ To limit the effort applied for pulling
This universal load cell is recommended for its simplicity and quick lifting capability.
 
LC104 Clamp On Load Cell Dimension:mm
                                           
Wire Rope TensionCap.Wire Rope Dia.HLL1BB1
1t1tØ6-14117160187645
2t1tØ10-18117160187645
5t2tØ16-26117160187645
10-20t5-10tØ24-361702601810868
20t10tØ24-361752721811272

Note:To output 4-20mA, 0-5V, 0-10V, an external transmitter is required;
 
LC104 Clamp On Load Cell Technical Parameter:
Wire Rope Size:1/2/3/5/10t
Sensitivity:(1.0±0.1%) mV/VOperating Temperature Range:-30~+70℃
Combined Error:±0.1% F.SMaximum Safe Over Load:150%F.S
Creep Error(30min):±0.02% F.SUltimate Over Load:300%F.S
Zero Balance:±1% F.SRecommend Excitation Vol.:10~12V DC
Temp. Effect On Zero:±0.02% F.S/10℃Maximum Excitation Voltage:15V DC
Temp. Effect On Span:±0.02% F.S/10℃Sealing Class:IP67
Input Resistance:385±5ΩElement Material:Alloy Steel, Stainless Steel
Output Resistance:352±2ΩCable:Length=1m
Insulation Resistance:≥5000MΩCitation:GB/T7551-2008/ OIML R60