Explosion Proof Load Cell
LC708
LC708 Explosion Proof Load Cell / flame proof sensor ATEX/IECEx certified (Ex d IIC T6) for hazardous areas like oil & gas. Stainless steel construction with IP67 rating ensures corrosion/impact resistance. ±0.1% accuracy with overload protection. Ideal for tanks, reactors and safety-critical weighing.
Quantity:
LC708 Explosion Proof Load Cell / flame proof sensor ATEX/IECEx certified (Ex d IIC T6) for hazardous areas like oil & gas. Stainless steel construction with IP67 rating ensures corrosion/impact resistance. ±0.1% accuracy with overload protection. Ideal for tanks, reactors and safety-critical weighing. ( explosion proof occupancy sensor, explosion proof load cell, flame proof sensor )
LC708 Explosion Proof Load Cell Features:
High temperature explosion proof occupancy sensor load cell, planar load-bearing, with a reasonable structure. The bearing mechanism is simple and reliable, easy to use, and easy to install. It is widely used in weighing systems such as continuous casting ladle scales, tundish scales, and overhead crane scales in the steel industry.
LC708 Explosion Proof Load Cell Dimension:mm

| Capacity | A | B | C | D | E | F | G | H | H1 | K | L | M | P | Q | S | W | X |
| (t) | (mm) | ||||||||||||||||
| 50 | 450 | 398 | 80 | Φ22 | 32 | 25.5 | Φ26 | 130 | 105 | 340 | 40 | M20×30 | 75 | 110 | 57 | 68 | 120 |
| 100 | 500 | 444 | 90 | Φ26 | 38 | 28.5 | Φ30 | 143 | 118 | 370 | 44 | M24×36 | 90 | 130 | 62 | 80 | 140 |
| 150 | 560 | 500 | 90 | Φ26 | 38 | 32 | Φ33 | 158 | 133 | 410 | 44 | M24×36 | 102 | 150 | 69 | 94 | 160 |
| 200 | 620 | 560 | 90 | Φ26 | 40 | 32 | Φ33 | 175 | 150 | 450 | 44 | M24×40 | 110 | 160 | 76 | 114 | 180 |
LC708 Explosion Proof Load Cell Technical Parameter:
| Rated Load: | 50~200t | ||
| Sensitivity: | 2.0±0.001mV/V | Operating Temp. Range: | -30~+70℃ |
| Combined Error: | ±0.3%F.S | Safe Over Load: | 150%F.S |
| Creep Error(30min): | ±0.02%F.S | Ultimate Over Load: | 250%F.S |
| Zero Balance: | ±1.0% F.S | Recommend Excitation: | 10~12V DC |
| Temp. Effect On Zero: | ±0.02% F.S/10℃ | Maximum Excitation: | 15V DC |
| Temp. Effect On Span: | ±0.02% F.S/10℃ | Sealing Class: | IP67/IP68 |
| Input Resistance: | 775±5Ω | Element Material: | Alloy/Stainless Steel |
| Output Resistance: | 700±2Ω | Cable: | 1m~12m |
| Insulation Resistance: | ≥5000MΩ | Citation: | GB/T7551-2008/OIMLR60 |