image
image
image
image
Weighbridge beam load cell

Beam Load Cell

LC116
LC116 Weighbridge beam load cell / Weigh beam load cell is a robust, high-precision sensor designed for industrial weighing applications. Constructed from alloy steel, it offers excellent resistance to side loads and overloads. LC116 Weighbridge beam load cell / Weigh beam load cell with an accuracy of 0.03% FS, IP67+ protection, and a capacity range of 5~40t, LC116 Weighbridge beam load cell / Weigh beam load cellis ideal for platform scales, hoppers, and process control. Features include easy installation, long-term stability, and 5-15V DC excitation. Desb load cell widely used in logistics, manufacturing, and food processing.
Quantity:
Contact Now
add to cart
All Products
LC116 Weighbridge beam load cell / Weigh beam load cell is a robust, high-precision sensor designed for industrial weighing applications. Constructed from alloy steel, it offers excellent resistance to side loads and overloads. LC116 Weighbridge beam load cell / Weigh beam load cell with an accuracy of 0.03% FS, IP67+ protection, and a capacity range of 5~40t, LC116 Weighbridge beam load cell / Weigh beam load cellis ideal for platform scales, hoppers, and process control. Features include easy installation, long-term stability, and 5-15V DC excitation. Desb load cell widely used in logistics, manufacturing, and food processing. ( beam load cell, Weigh beam load cell, Weighbridge beam load cell )
 
LC116 Beam Load Cell Specification:
✅ LC116 Beam Load Cell are available in the capacities 1Klb to100Klb.
✅ Alloy steel construction, potted by adhesive inside, oil-proof, waterproof anti-corrosive gas or medium making it suitable for all kinds of environments.
✅ Dual shear beam, easy installation, suitable for electronic truck scales, track scales, automobile testing facilities and other electronic weighing devices.
 
LC116 Beam Load Cell Dimensions: Unit: mm
 
 
       Cap.              L         L1             L2HH1W      A             B      
10~40t240200205264562696.5
LC116 Beam Load Cell Technical Parameter:
Rated Load:10~40tOperating Temp. Range:-30~+70℃
Sensitivity:(2.0±0.1%) mV/VMax. Safe Over Load:150,120 (40~50t)%F.S
Combined Error:±0.02% F.SUltimate Over Load:300,200(40~50t)%F.S
Creep Error(30min):±0.01% F.SRecommend Excitation:10~12V DC
Zero Balance:±1% F.SMaximum Excitation:15V DC
Tco:±0.02% F.S/10℃Sealing Class:IP67/IP68
Tc Span:±0.02% F.S/10℃Element Material:Alloy/Stainless Steel
Input Resistance:750±5ΩCitation:GB/T7551-2008/ OIML R60
Insulation Resistance:≥5000MΩCable:Length=13m
Output Resistance:703±2Ω,703±5 Ω(L≥15m)Mode Of Connection:Red(Input+),Black(Input-),Green(Output+),White(Output-)