Circular Load Cell
LC6301
LC6301 Circular Load Cell / circular Column load cell through hole high-precision load cell features a hollow ring design for measuring tension, compression, and radial forces. Ideal for industrial weighing, machinery monitoring, and structural testing, it offers robust durability, high accuracy, and easy installation. LC6301 Column circular load cell / circular Column load cell compatible with various signal outputs, it ensures reliable performance in harsh environments.
Quantity:
LC6301 Circular Load Cell / circular Column load cell through hole high-precision load cell features a hollow ring design for measuring tension, compression, and radial forces. Ideal for industrial weighing, machinery monitoring, and structural testing, it offers robust durability, high accuracy, and easy installation. LC6301 Column circular load cell / circular Column load cell compatible with various signal outputs, it ensures reliable performance in harsh environments. ( circular load cell, circular Column load cell, Column circular load cell )
LC6301 Circular Load Cell Introduction:
✅ Hollow design, high precision, strong anti-bias load capacity;
✅ Suitable for extrusion, assembly, material tank, material mechanics testing machine and other fields;
LC6301 Circular Load Cell Application:
Pressure Testing Machine, Large Hydraulic Machinery Equipment, Large Range Force Measurement and Various Weighing Testing in Colleges and Universities, Large Industrial Weighing Control System;
LC6301 Circular Load Cell Features:
✅ Self-restoring rocker pin load cell.
✅ Upper and lower inhibitor design, easy to installation.
✅ Dynamic respond, and super capacity for anti-overload.
✅ Application to truck scale, railway scale, axle scale, storage scale and other weighing equipment.
LC6301 Circular Load Cell Dimension:mm

| Size | Capacity | ||||||||||
| 500kg | 1t | 2t | 3t | 5t | 10t | 20t | 50t | 100t | 200t | 300t | |
| A | 40 | 62 | 62 | 62 | 60 | 60 | 90 | 115 | 166 | 236 | 236 |
| B | 35 | 55 | 55 | 55 | 36 | 36 | 68 | 109 | 141 | 190 | 195 |
| C | 10 | 18 | 18 | 18 | 18 | 18 | 43 | 80 | 85 | 120 | 120 |
| D | 50 | 74 | 70 | 70 | 70 | 80 | 80 | 110 | 110 | 120 | 120 |
| E | 3 | 4 | 4 | 4 | 4 | 4 | 5 | 7 | 7 | 7 | 7 |
Note:The overall dimensions can be customized according to the customer's requirements:
LC6301 Circular Load Cell Technical Parameter:
| Rated Load: | 0.5/1/2/3/5/10/20/50/100/200/300t | ||
| Sensitivity: | (1.0±0.1%) mV/V | Operating Temp. Range: | -20~+60℃ |
| Hysteresis: | ±0.3% F.S | Compensated Temp: | -10~+50℃ |
| Combined Error: | ±0.03% F.S | Max. Safe Over Load: | 150%F.S |
| Creep Error(30min): | ±0.1% F.S | Ultimate Over Load: | 250%F.S |
| Zero Balance: | ±2% F.S | Recommend Excitation: | 10~12V DC |
| Temp. Effect On Zero: | ±0.01% F.S/10℃ | Maximum Excitation: | 15V DC |
| Temp. Effect On Span: | ±0.05% F.S/10℃ | Sealing Class: | IP67/IP68 |
| Input Resistance: | 385±10Ω | Element Material: | -A: Alloy Steel,-SS: Stainless Steel |
| Output Resistance: | 350±3Ω | Cable: | Length=12m(0.5~10t),18m(30~300t) |
| Insulation Resistance: | ≥5000MΩ | Citation: | GB/T7551-2008/ OIML R60 |